Video StormVMX (All models, v2.7) [Serial]Video StormVideo Storm VMX (All models, v2.7)(Fast)[Serial]devices_sm/KnoxRS8x8HB.GIFdevices_lg/KnoxRS8x8HB.GIF5/10/2009 5:35:35 PM1/10/2012 2:03:03 PMlua_genDriverWorks
avswitch
serial
False
True
False
0
9600 8 none 1 none 232
11
9
VMX driver \n
Front panel and IR control will be locked out.
Driver setup PLEASE READ!\n
Requires firmware 2.4.0 or later.
1. The Video selection properties are READ ONLY states
2. Make sure you fully connect all the "connections" used to both inputs AND outputs for VIDEO
3. You can also paste the following into in the LUA comman window (to verify communication), then click execute
ExecuteCommand("Read_status")
This will readback from the switch. Check the properties tab next and verify that
Readback config status = OK
4. If you want to save the current switch settings to flash as power on defaults, use this LUA command
sendrs232("CF7F\r")
sendrs232("CF7T\r")
5. The "Enable zone powerdown" property will automatically powerdown each output zone when not in use.
\n\n
Additional Commands\n
Read_status: This will poll the CMX to get the device status and update all properties.
Normally this is not needed since the FP and IR are locked, but can be a useful debug tool.
The Readback config status property is set by this command.
They will transition from CurrentState => waiting => OK or ERROR or TIMEOUT.
OK means functioning properly. TIMEOUT means no response from CMX.
ERROR on config status means the device config is incorrect.
Save_state X: This will save the current input/output/volume settings to flash slot X. This useful for a
quick recall or doorbell/intercom mode.
Recall_state X: This will recall a previously saved state from flash slot X.
Send_serial: This will send a specified generic serial command.
Enable zone powerdown
LIST
- On
- Off
Off
false
Readback config status
LIST
- OK
- WAITING
- TIMEOUT
- ERROR
OK
true
Video select 1
RANGED_INTEGER
0
9
0
true
Video select 2
RANGED_INTEGER
0
9
0
true
Video select 3
RANGED_INTEGER
0
9
0
true
Video select 4
RANGED_INTEGER
0
9
0
true
Video select 5
RANGED_INTEGER
0
9
0
true
Video select 6
RANGED_INTEGER
0
9
0
true
Video select 7
RANGED_INTEGER
0
9
0
true
Video select 8
RANGED_INTEGER
0
9
0
true
Video select 9
RANGED_INTEGER
0
9
0
true
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Read_status
Read device status over RS232
Send_serial
Sends given serial command
Cmd
STRING
Save_state_X
Save current Output settings to flash slot X
Slot
RANGED_INTEGER
1
8
Recall_state_X
Recalls Output settings from flash slot X
Slot
RANGED_INTEGER
1
8
Configure_switch
Send switch config commands
5001
1
AVSWITCH
2
False
False
AVSWITCH
1
1
Serial RS-232
1
True
True
RS_232
2000
1
OUTPUT 1
5
False
True
COMPONENT
1000
1
INPUT 1
5
True
True
COMPONENT
7000
1
Room Selection - OUTPUT 1
7
False
True
VIDEO_SELECTION
2010
1
OUTPUT 2
5
False
True
COMPONENT
1010
1
INPUT 2
5
True
True
COMPONENT
7010
1
Room Selection - OUTPUT 2
7
False
True
VIDEO_SELECTION
2020
1
OUTPUT 3
5
False
True
COMPONENT
1020
1
INPUT 3
5
True
True
COMPONENT
7020
1
Room Selection - OUTPUT 3
7
False
True
VIDEO_SELECTION
2030
1
OUTPUT 4
5
False
True
COMPONENT
1030
1
INPUT 4
5
True
True
COMPONENT
7030
1
Room Selection - OUTPUT 4
7
False
True
VIDEO_SELECTION
2040
1
OUTPUT 5
5
False
True
COMPONENT
1040
1
INPUT 5
5
True
True
COMPONENT
7040
1
Room Selection - OUTPUT 5
7
False
True
VIDEO_SELECTION
2050
1
OUTPUT 6
5
False
True
COMPONENT
1050
1
INPUT 6
5
True
True
COMPONENT
7050
1
Room Selection - OUTPUT 6
7
False
True
VIDEO_SELECTION
2060
1
OUTPUT 7
5
False
True
COMPONENT
1060
1
INPUT 7
5
True
True
COMPONENT
7060
1
Room Selection - OUTPUT 7
7
False
True
VIDEO_SELECTION
2070
1
OUTPUT 8
5
False
True
COMPONENT
1070
1
INPUT 8
5
True
True
COMPONENT
7070
1
Room Selection - OUTPUT 8
7
False
True
VIDEO_SELECTION
2080
1
OUTPUT 9
5
False
True
COMPONENT
1080
1
INPUT 9
5
True
True
COMPONENT
7080
1
Room Selection - OUTPUT 9
7
False
True
VIDEO_SELECTION
1090
1
INPUT 10
5
True
True
COMPONENT
1100
1
INPUT 11
5
True
True
COMPONENT