Video StormVMX (All models, v2.7) [Serial]Video StormVideo Storm VMX (All models, v2.7)(Fast)[Serial]devices_sm/KnoxRS8x8HB.GIFdevices_lg/KnoxRS8x8HB.GIF5/10/2009 5:35:35 PM1/10/2012 2:03:03 PMlua_genDriverWorks avswitch serial False True False 0 9600 8 none 1 none 232 11 9 VMX driver \n Front panel and IR control will be locked out. Driver setup PLEASE READ!\n Requires firmware 2.4.0 or later. 1. The Video selection properties are READ ONLY states 2. Make sure you fully connect all the "connections" used to both inputs AND outputs for VIDEO 3. You can also paste the following into in the LUA comman window (to verify communication), then click execute ExecuteCommand("Read_status") This will readback from the switch. Check the properties tab next and verify that Readback config status = OK 4. If you want to save the current switch settings to flash as power on defaults, use this LUA command sendrs232("CF7F\r") sendrs232("CF7T\r") 5. The "Enable zone powerdown" property will automatically powerdown each output zone when not in use. \n\n Additional Commands\n Read_status: This will poll the CMX to get the device status and update all properties. Normally this is not needed since the FP and IR are locked, but can be a useful debug tool. The Readback config status property is set by this command. They will transition from CurrentState => waiting => OK or ERROR or TIMEOUT. OK means functioning properly. TIMEOUT means no response from CMX. ERROR on config status means the device config is incorrect. Save_state X: This will save the current input/output/volume settings to flash slot X. This useful for a quick recall or doorbell/intercom mode. Recall_state X: This will recall a previously saved state from flash slot X. Send_serial: This will send a specified generic serial command. Enable zone powerdown LIST On Off Off false Readback config status LIST OK WAITING TIMEOUT ERROR OK true Video select 1 RANGED_INTEGER 0 9 0 true Video select 2 RANGED_INTEGER 0 9 0 true Video select 3 RANGED_INTEGER 0 9 0 true Video select 4 RANGED_INTEGER 0 9 0 true Video select 5 RANGED_INTEGER 0 9 0 true Video select 6 RANGED_INTEGER 0 9 0 true Video select 7 RANGED_INTEGER 0 9 0 true Video select 8 RANGED_INTEGER 0 9 0 true Video select 9 RANGED_INTEGER 0 9 0 true Debug Mode LIST Off Print Log Print and Log Off false Read_status Read device status over RS232 Send_serial Sends given serial command Cmd STRING Save_state_X Save current Output settings to flash slot X Slot RANGED_INTEGER 1 8 Recall_state_X Recalls Output settings from flash slot X Slot RANGED_INTEGER 1 8 Configure_switch Send switch config commands 5001 1 AVSWITCH 2 False False AVSWITCH 1 1 Serial RS-232 1 True True RS_232 2000 1 OUTPUT 1 5 False True COMPONENT 1000 1 INPUT 1 5 True True COMPONENT 7000 1 Room Selection - OUTPUT 1 7 False True VIDEO_SELECTION 2010 1 OUTPUT 2 5 False True COMPONENT 1010 1 INPUT 2 5 True True COMPONENT 7010 1 Room Selection - OUTPUT 2 7 False True VIDEO_SELECTION 2020 1 OUTPUT 3 5 False True COMPONENT 1020 1 INPUT 3 5 True True COMPONENT 7020 1 Room Selection - OUTPUT 3 7 False True VIDEO_SELECTION 2030 1 OUTPUT 4 5 False True COMPONENT 1030 1 INPUT 4 5 True True COMPONENT 7030 1 Room Selection - OUTPUT 4 7 False True VIDEO_SELECTION 2040 1 OUTPUT 5 5 False True COMPONENT 1040 1 INPUT 5 5 True True COMPONENT 7040 1 Room Selection - OUTPUT 5 7 False True VIDEO_SELECTION 2050 1 OUTPUT 6 5 False True COMPONENT 1050 1 INPUT 6 5 True True COMPONENT 7050 1 Room Selection - OUTPUT 6 7 False True VIDEO_SELECTION 2060 1 OUTPUT 7 5 False True COMPONENT 1060 1 INPUT 7 5 True True COMPONENT 7060 1 Room Selection - OUTPUT 7 7 False True VIDEO_SELECTION 2070 1 OUTPUT 8 5 False True COMPONENT 1070 1 INPUT 8 5 True True COMPONENT 7070 1 Room Selection - OUTPUT 8 7 False True VIDEO_SELECTION 2080 1 OUTPUT 9 5 False True COMPONENT 1080 1 INPUT 9 5 True True COMPONENT 7080 1 Room Selection - OUTPUT 9 7 False True VIDEO_SELECTION 1090 1 INPUT 10 5 True True COMPONENT 1100 1 INPUT 11 5 True True COMPONENT